Characterization of Wastewater in The University Campus: A Case Study in Universitas Andalas, Indonesia
DOI:
https://doi.org/10.25077/dampak.21.2.18-26.2024Keywords:
Characteristics, Domestic Wastewater, Campus, Quality Standards, Hazardous WastewaterAbstract
This study aims to analyze wastewater characteristics at Universitas Andalas Campus Limau Manis Padang encompassing physical, chemical, and biological attributes, while comparing them to established quality standards and estimating mass loading. Wastewater samples were collected from various sources, including domestic and specific wastewater. Sampling locations and times were chosen based on peak activity. Physical analysis revealed temperature ranging from 27.32 to 31.5°C and TSS concentrations from 130.00 to 580.00 mg/L. Chemical parameters displayed significant variation, with pH values between 2.27 and 9.70, BOD5 concentrations spanning 108.46 to 506.59 mg/L, COD levels from 162.70 to 1,428.00 mg/L, and oil and grease content from 0.20 to 84.31 mg/L. N-total ranged from 47.07 to 309.16 mg/L, sulfate from 72.70 to 1,480.00 mg/L, and phosphate from 1.14 to 98.15 mg/L. Biological attributes showed total coliform counts exceeding 10,000 colonies per 1,000 mL, all surpassing quality standards. Notably, the BOD5/COD ratio indicated low biodegradable quality (values <0.5) for certain wastewater sources. Greywater emerged as the primary pollutant, with substantial mass loadings. Eventually, this study underscores the vital need for wastewater treatment before environmental discharge.
Keywords:Â Characteristics, Domestic Wastewater, Campus, Quality Standards, Hazardous Wastewate
Â
References
Al Amin, C., Mahmud, & Stiyati, N. (2020). Perencanaan dan perancangan bangunan instalasi pengolahan air limbah domestik terpusat untuk kawasan ULM Banjarbaru [Planning and design of central domestic wastewater treatment plant for the ULM Banjarbaru area]. JTAM Teknik Lingkungan Universitas Lambung Mangkurat, 3(2). Universitas Lambung Mangkurat [in Bahasa]
Al-Rosyid, L.M., & Mangkoedihardjo, S. (2019). Relationship between BOD/COD Ratio And Octanol/Water Partition Coefficient For Glucose, Lactose, Sucrose, Formaldehyde, Acetic Acid And Oxalic Acid.
Al-Sulaiman, A., & Khudair, B.H. (2018). Correlation Between BOD5 And COD For Al-Diwaniyah Wastewater Treatment Plants To Obtain The Biodigrability Indices 1.


Albalawneh, A., & Chang, T. (2015). Review Of The Greywater And Proposed Greywater Recycling Scheme For Agricultural Irrigation Reuses.
American Public Health Association (APHA), Standard Methods for the Examination of Water and Wastewater, 19th Edition, Washington DC, 2005
Azadi, N.A, Falazadeh, R.A. and Sadeghi, S. 2015. Dairy wastewater treatment plant in removal of organic pollution: a case study in Sanandaj, Iran. Environmental Health Engineering. and Management Journal. 2(2):73-77
Komala, P. S., Ruslinda, Y., & Zurienra, J. (2020). Studi Kuantitas Air Buangan Kampus Universitas Andalas Limau Manis Padang. Serambi Engineering, 5(2), 1050-1062. p-ISSN: 2528-3561, e-ISSN: 2541-1934 [in Bahasa]
Liu, H. (2013). A Comparative Study in Pretreatments of Acid Chemical Wastewater by Electrochemical Oxidation and Ozonation. Journal of Electrochemistry.
Ministry of Environment and Forestry. (2016). Regulation of the Minister of Environment and Forestry Number P.68/MENLHK-SETJEN/2016 of 2016 concerning Domestic Wastewater Quality Standards (No. P.68/MENLHK-SETJEN/2016). Jakarta: Ministry of Environment and Forestry [in Bahasa]
Muhardi, J.S., & Nurhadi, N. (2022). Pengaruh Kecepatan Aliran Air Dan Massa Campuran Media Filtrasi Terhadap Kadar Polutan Hasil Pengolahan Air Limbah. Jurnal Aplikasi Dan Inovasi Ipteks "Soliditas" (J-Solid) [in Bahasa]


Budeiz, V., & Aguiar, A. (2020). Monitoring And Relationship of Cod And Bod5 Parameters In Afluent And Treated Sewage From Itajubá And Pedralva Cities, MG. Periódico Tchê QuÃmica.
Oteng-Peprah, M., de Vries, N.K., & Acheampong, M.A. (2018). Greywater characterization and generation rates in a peri urban municipality of a developing country. Journal of environmental management, 206, 498-506 .
Oyem, I.M., Oyem, H.H., & Imarhiagbe, E.E. (2021). Microbial and Physicochemical Qualities of Septic Tank Wastewater: An Evaluation. East African Journal of Health and Science.
Partal, R., Hocaoglu, S. M., Oktem Olgun, E., Canli, O., & Yigit, N. O. (2020). Treatability of Medical Laboratory Wastewater by Membrane Bioreactor (MBR)
Saha, P., Shide, O. Sarkar, S. 2017. Phytoremediation of industrial mine wastewater using water hyacinth. International Journal of Phytoremediation. 19(1):87-96.doi:10.1080/15226514.2016.1216078
Samudro, G and Mangkoedihardjo, S. 2010. Review on the BOD, COD, and BOD/COD ratio: a triangle zone for toxic biodegradable and stable levels. International Journal of Academic Research, 2(4)
Tchobanoglous, G., Stensel, H. D., & Tsuchihashi, R. (2014). Wastewater engineering: Treatment and resource recovery. Metcalf & Eddy, Inc.
Todt, D., Heistad, A., & Jenssen, P.D. (2015). Load and distribution of organic matter and nutrients in a separated household wastewater stream. Environmental Technology, 36, 1584 - 1593.
Zhang, P., Sun, M., Liang, J., Xiong, Z., Liu, Y., Peng, J., Yuan, Y., Zhang, H., Zhou, P., & Lai, B. (2024). pH-modulated oxidation of organic pollutants for water decontamination: A deep insight into reactivity and oxidation pathway. Journal of hazardous materials, 471, 134393
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Yenni Ruslinda, Ansiha Nur, Puti Sri Komala, Leni Leni, Rinda Andhita Regia, Regina Mardatillah

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.